Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 60
maximum ceiling height = 3 m; maximum load Ed,fi = 81 kN/m  
Classified by HFA  
Thermal performance U
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr)
Ln,w (Cl)
Rating by HFA  
Mass per unit area m 49,6 kg/m2
 

data sheet internal wall
iwrxxo15b-02 (pdf, 250 KB)

Note

Construction layer B: combination with sill: STEICO GLVL R 60/120

The fire resistance is only valid when wall is used as partition with only one side exposed to fire.

Only for registered members after logging in.
timber frame construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 25,0 gypsum plaster board type DF 2x12,5mm 0,250 10 800 1,050 A2
B 120,0 STEICO LVL R (57/...; e=625) 0,130 70-200 480 2,100 D
C 120,0 STEICOzell [039; 40] 0,039 1-3 40 2,100 E
D 25,0 gypsum plaster board type DF 2x12,5mm 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 11,2 kg
Share of renewable materials of total weight 20,49 %
Global warming potential (GWP-T) 0,248 kgCO2Äqv.
Energy use of Primary Energy 351,4 MJ
Share of renewable Primary Energy 21,0 %
∑ΔOI3 17,1
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 16,798 -16,550 0,248 73,716 151,319 225,035 277,708 15,297 293,004 0,055 0,025 1.8012867E-6 0,009

Source: Steico SE

Last update 02.08.2023/hfa.eco2soft